StacksVerified U.S. regulatory reference

40 CFR Part 63, Table 3

Verified against eCFR.gov as of June 20, 2026View official text on eCFR.gov

You must comply with the emission limits that apply to your affected source in the following table as required by § 63.3490(d).

If you use the control efficiency/outlet concentration option to comply with the emission limitations for any coating operation(s) . . .Then you must comply with one of the following by using an emissions control system to . . .
1. in a new or reconstructed affected sourcea. reduce emissions of total HAP, measured as THC (as carbon), a by 97 percent; orb. limit emissions of total HAP, measured as THC (as carbon), a to 20 ppmvd at the control device outlet and use a PTE.
2. in an existing affected sourcea. reduce emissions of total HAP, measured as THC (as carbon), a by 95 percent; orb. limit emissions of total HAP, measured as THC (as carbon), a to 20 ppmvd at the control device outlet and use a PTE.

a You may choose to subtract methane from THC as carbon measurements.